Jet mixing on pharmaceutical effluent plant

Application

To prevent stratification of effluent in two 1287 m3 (18m dia. x 5m max. depth) balance tanks on a Pharmaceutical plant. Propeller Mixers were not suitable because the liquor operating levels varied and the client did not want any in-tank maintenance.

 

Solution

Transvac installed a stainless steel Jet mixing system on a pipework manifold. A total of seventeen transvac size 4 Jet Mixers were used in each tank discharging four times the liquor flow provided by the motive pump. Additional secondary mixing induced by the Mixer discharge plumes further enhanced the mixing pattern. Using a 15 kW Centrifugal Pump to provide the mixing energy of 11 watts/m3 the Jet mixers induced a tank turnover rate of less than 1.6 hours (at max. liquor level) which ensured the whole contents were thoroughly mixed.


Jet Mixers installed in effluent tank
 
Jet Mixers installed in effluent tank

Advantages of Jet Mixers

  • No moving parts
  • No splashing or aerosol created
  • Operates at variable depths
  • No bridges or bearings used
  • No in-tank maintenance needed
  • Evenly distributes mixing
  • Controllable mixing
  • Simple, reliable and robust
Transvac Systems Ltd, Monsal House, Bramble Way, Alfreton, Derbyshire, DE55 4RH, England
Telephone: +44 (0)1773 83 11 00 Facsimile: +44 (0)1773 83 11 23 E-mail: sales@transvac.co.uk